Hello!  Welcome to Haochen Technology! [Login][Register]
NewsNew products
Data centerUsed products

All equipment categories

News and trends

Promotion information

Product details

SaleNewport GON40-L Newport GON40-L Goniometer Stage

Views:640

Product parameters

Option Calibrated Delivery cycle Warranty Condition
No -- 3month 80% new
Location Serial Number State Data download
Shenzhen City Intact
Budget Price: TEL
Update date:2022-04-21
Contact phone:+86-755-86016691

*Product description

Product Description:
The GON40-L lower goniometer stage rotates the object around an axis that is not obstructed by the platform itself and is centered on the top of the platform. The GON series goniometer rotary stages use actuator-driven, spring-loaded precision dovetail slides to reduce backlash commonly found in similar worm gear-driven stages. The spring-loaded design has the added advantage of interchangeable actuators, allowing you to select adjustment sensitivity from a variety of actuators such as precision adjustment screws, differential micrometers or electric actuators. GON series stages of the same size can be used individually or stacked. In a stacked configuration, the axes of rotation will intersect each other for orthogonal motion around a common point in space. The GON40-L goniometer stage has a ±5° range of rotational motion when used with an actuator with 13 mm travel. The motion of the goniometer stage can be securely locked using the hex screws on the side of the stage.

Detailed information

Product Description:
The GON40-L lower goniometer stage rotates the object around an axis that is not obstructed by the platform itself and is centered on the top of the platform. The GON series goniometer rotary stages use actuator-driven, spring-loaded precision dovetail slides to reduce backlash commonly found in similar worm gear-driven stages. The spring-loaded design has the added advantage of interchangeable actuators, allowing you to select adjustment sensitivity from a variety of actuators such as precision adjustment screws, differential micrometers or electric actuators. GON series stages of the same size can be used individually or stacked. In a stacked configuration, the axes of rotation will intersect each other for orthogonal motion around a common point in space. The GON40-L goniometer stage has a ±5° range of rotational motion when used with an actuator with 13 mm travel. The motion of the goniometer stage can be securely locked using the hex screws on the side of the stage.

Similar hot instrument

Friendship recommendation

Cooperative client:

more>>

Domestic instrument:

more>>

Import instrument:

more>>

Metrology calibration:

more>>

Copyright © Copyright © 2007 All Rights Reserved. Copyright© 2003-2015 Shenzhen Haochen Electronic Technology Co.,ltd . All Rights Reserved.   [粤ICP备14101712号-1] [Legal Adviser]

Address:8th Floor, NO.221, Niucheng Road, Xili Town,Nanshan District, Shenzhen, Guangdong Province, China,518055

QQ online service:  Service hotline:0755-86016691  Tel:13715327187  Fax:+86 0755-86641139-816

E-mail:info@wl95.com