Handheld spectrum analyzer Portable spectrum analyzer Benchtop spectrum analyzer
Sampling oscilloscope host Sampling oscilloscope Precision Timebase Reference Module Sampling oscilloscope module Mixed signal oscilloscope
Error detector <4.25G bit error rate analyzer Error detector <10G Error detector >10G Error detector >100G Clock Synthesizer
Handheld optical power meter Benchtop optical power meter Light wave multimeter host Light wave multimeter module Optical power meter probe Optical power module
Point light source Adjustable light source Wide band light source UV light source Polarized Light Source Frequency sweep light source
General power source ER extinction ratio tester Digital multimeter General oscilloscope Digital source table Picoammeter Multimeter TEC SourceMeter Optical switch End face detection analyzer Light wave measurement system Optical tunable filter Laser displacement sensor Light modulator End face interferometer Light wave component analyzer Light wave transmitter Light wave receiver High speed Scanning Laser Photodiode Laser Diode/Module Detector
Polarization analyzer Signal quality analyzer Gas flow analysis equipment Network testing instrument Dispersion analyzer Fiber optic sensor analyzer Fiber optic strain distribution tester
Auto-coupling system Terahertz optical sampling and analysis system Intelligent optical link tester 参数分析仪 参数分析仪 Parameter analyzer Scan test system Tunable laser system Optical fiber testing system Measurement System of Relative Intensity Noise Optical Noise Analyzer
Cutting knife Optical fiber cutter Adapter Electrode rod Alignment machine Hot strip clamp The battery The blade Integrating sphere Laser clamp
Polarization controller Light wavelength meter Optical loss tester Ribbon optical fiber welding machine Optical vector analyzer Pulse power supply Optical test return loss(OTRL) Optical amplifier Displacement of the machine Laser welding machine Laser cutting machine Spectrophotometric colorimeter Gloss meter
WIFI TESTER Comprehensive tester Bluetooth tester WIFI BLUETOOTH Analyzer Instrument summary Wireless tester
Vector network analyzer measurement receiver for antenna Scalar network analyzer Antenna/feeder measurement instrument Handheld antenna and transmission line tester
Desktop spectrum analyzer Portable spectrum analyzer Handheld spectrum analyzer Wireless receiver Wireless terminal tester Site measurement and maintenance of paging, data communication, base station management, repeater, base station OEM
Analog signal generator Vector signal generator Function/arbitrary waveform signal generator Pulse code generator Video signal generator Television [TV] signal generator Audio signal generator Arbitrary waveform generator RF signal generator
Audio analyzer Cross domain analyzer Protocol analyzer Phase noise tester Impedance analyzer
Gas chromatographic analyzer Gas chromatographic analyzer components and accessories
Liquid chromatography analyzer Liquid chromatography analyzer components and accessories
Molecular spectrum analyzer Molecular spectrum analyzer components and accessories
Atomic absorption spectrum analyzer Atomic absorption spectrum analyzer components and accessories
Views:2016
| Option | Calibrated | Delivery cycle | Warranty | Condition |
|---|---|---|---|---|
| No | 0month | 12month | 80% new | |
| Location | Serial Number | State | Data download | |
| Shenzhen City | Unknown |
Powerful Measurement Management
The 3457A combines superb analog measuring capability with equally powerful measurement management. More than 1000 readings or whole measurement sequences can be stored in the 3457A for convenient and fast measurement throughput. The present dmm setup can be stored in the non-volatile state memory for convenient reconfiguration of the dmm.
Additional power from math functions can be obtained by using PASS/FAIL limit testing, NULL, SCALE, THERMISTOR linearization, and others. The power of total electronic calibration, including AC volts, makes it easy to maintain instrument performance.
Keeping with HP's long tradition of systems oriented digital multimeters, the 3457A has all the systems features you've come to expect plus more to make interfacing to your computer even easier - features like flexible formatting of ASCII, 16 bit binary, or 32 bit binary data and buffer memory so that you can take measurements with the 3457A at its highest speed. In addition, you'll find the VOLTMETER COMPLETE output and EXTERNAL TRIGGER input signals ideal for synchronizing other instrumentation with the 3457A. Finally, programmable front-rear terminal switching lets you measure two separate inputs without a scanner.
Hewlett-Packard Multimeter Language (HPML)
Another first for the 3457A DMM is an easy-to-use dmm language-HPML. Designed so that software written for today's multimeter will fit tomorrow's, HPML only asks you to define the parameters necessary to accomplish your measurement. For example, if you want to make a measurement on a 9 volt DC signal with .01% resolution, the command sequence is "DCV, 9, .01".
Control Interface Intermediate Language (CIIL) Option
With Option 700, the 3457A responds to standardized DMM CIIL commands via HP-IB. Physically and functionally identical to the standard 3457A, Option 700 adds the CIIL command set with a built-in Test Module Adapter (TMA) to the DMMs standard HPML. The 3457A is further enhanced by adding the functions of AC and DC current through CIIL through HP-IB.
Three Rear Panel Plug-In Options
Either one of three different optional assemblies may be used with the 3457A for different measurement capabilities. Using the multiplexer assemblies with enable up to ten signal channels to be scanned either sequentially or randomly. All of the functional capability offered through the normal front and rear input terminals is available for multiple inputs. Using the high voltage assembly allows single channel measurement of either AC or DC voltages at the rear panel.
For measurement flexibility, the 44491A Armature Relay Multiplexer Assembly offers eight two-wire channels and two current/actuator channels. Under software control, the eight two-wire channels can be reconfigured to four 4-wire ohm channels. The two current channels offer automatic make-before-break switching so that the path for current as high as 1.5 A is never broken. In addition, these two channels can be used as external device actuator channels. Each channel can switch up to 150V. The general purpose multiplexer can close a channel and make a measurement at a maximum rate of 33 channels per second.
For higher speed scanning, the 44492A Reed Relay Multiplexer Assembly offers ten two-wire channels. The 44492A is useful for switching DCV, ACV, AC+DCV, two wire ohms, frequency and period measurement signals with a maximum amplitude of 125 V. The Reed Relay Multiplexer can close a relay and make a measurement at a maximum rate of 300 channels per second.
For measurement of voltages up to 1414 V peak, the 44497A High Voltage Assembly offers a 1000:1 attenuator input (channel 1) for the high voltage measurements. In addition, the other rear terminal input (channel 0) can be utilized to perform conventional VDC, VAC, Two-wire and Four-wire Ohms, Period, Frequency, DCI, and ACI measurements. Using the 44497A with the 3457A in the 6 1/2 digit mode will yield a resolution of 1 mV for a 1000 V input. Implementing the MATH Scale function will have the 3457A LCD display the measurement results in the correct units of kilovolts.
HP 3457A has seven functions with 3 1/2 to 6 1/2 digits of resolution extendable to 7 1/2 digits at reading rates from 1 reading every 2 seconds to 1350 rds/s and basic DC volts accuracy as good as 5 ppm. In addition, the input of the 3457A can be expanded up to ten channels with either of the optional plug-in multiplexer assemblies. On the bench, the front panel operation is extremely flexible and comprehensive. In systems, the Hewlett-Packard Interface Bus (HP-IB) is standard.
| HP 3457A has seven functions with 3 1/2 to 6 1/2 digits of resolution extendable to 7 1/2 digits at reading rates from 1 reading every 2 seconds to 1350 rds/s and basic DC volts accuracy as good as 5 ppm. In addition, the input of the 3457A can be expanded up to ten channels with either of the optional plug-in multiplexer assemblies. On the bench, the front panel operation is extremely flexible and comprehensive. In systems, the Hewlett-Packard Interface Bus (HP-IB) is standard. | |||
|
|||
|
Powerful Measurement Management The 3457A combines superb analog measuring capability with equally powerful measurement management. More than 1000 readings or whole measurement sequences can be stored in the 3457A for convenient and fast measurement throughput. The present dmm setup can be stored in the non-volatile state memory for convenient reconfiguration of the dmm. Additional power from math functions can be obtained by using PASS/FAIL limit testing, NULL, SCALE, THERMISTOR linearization, and others. The power of total electronic calibration, including AC volts, makes it easy to maintain instrument performance. Keeping with HP's long tradition of systems oriented digital multimeters, the 3457A has all the systems features you've come to expect plus more to make interfacing to your computer even easier - features like flexible formatting of ASCII, 16 bit binary, or 32 bit binary data and buffer memory so that you can take measurements with the 3457A at its highest speed. In addition, you'll find the VOLTMETER COMPLETE output and EXTERNAL TRIGGER input signals ideal for synchronizing other instrumentation with the 3457A. Finally, programmable front-rear terminal switching lets you measure two separate inputs without a scanner. Hewlett-Packard Multimeter Language (HPML) Another first for the 3457A DMM is an easy-to-use dmm language-HPML. Designed so that software written for today's multimeter will fit tomorrow's, HPML only asks you to define the parameters necessary to accomplish your measurement. For example, if you want to make a measurement on a 9 volt DC signal with .01% resolution, the command sequence is "DCV, 9, .01". Control Interface Intermediate Language (CIIL) Option With Option 700, the 3457A responds to standardized DMM CIIL commands via HP-IB. Physically and functionally identical to the standard 3457A, Option 700 adds the CIIL command set with a built-in Test Module Adapter (TMA) to the DMMs standard HPML. The 3457A is further enhanced by adding the functions of AC and DC current through CIIL through HP-IB. Three Rear Panel Plug-In Options Either one of three different optional assemblies may be used with the 3457A for different measurement capabilities. Using the multiplexer assemblies with enable up to ten signal channels to be scanned either sequentially or randomly. All of the functional capability offered through the normal front and rear input terminals is available for multiple inputs. Using the high voltage assembly allows single channel measurement of either AC or DC voltages at the rear panel. For measurement flexibility, the 44491A Armature Relay Multiplexer Assembly offers eight two-wire channels and two current/actuator channels. Under software control, the eight two-wire channels can be reconfigured to four 4-wire ohm channels. The two current channels offer automatic make-before-break switching so that the path for current as high as 1.5 A is never broken. In addition, these two channels can be used as external device actuator channels. Each channel can switch up to 150V. The general purpose multiplexer can close a channel and make a measurement at a maximum rate of 33 channels per second. For higher speed scanning, the 44492A Reed Relay Multiplexer Assembly offers ten two-wire channels. The 44492A is useful for switching DCV, ACV, AC+DCV, two wire ohms, frequency and period measurement signals with a maximum amplitude of 125 V. The Reed Relay Multiplexer can close a relay and make a measurement at a maximum rate of 300 channels per second. For measurement of voltages up to 1414 V peak, the 44497A High Voltage Assembly offers a 1000:1 attenuator input (channel 1) for the high voltage measurements. In addition, the other rear terminal input (channel 0) can be utilized to perform conventional VDC, VAC, Two-wire and Four-wire Ohms, Period, Frequency, DCI, and ACI measurements. Using the 44497A with the 3457A in the 6 1/2 digit mode will yield a resolution of 1 mV for a 1000 V input. Implementing the MATH Scale function will have the 3457A LCD display the measurement results in the correct units of kilovolts. |
|||