Hello!  Welcome to Haochen Technology! [Login][Register]
NewsNew products
Data centerUsed products

Item listings

Comprehensive ranking

Popularity from high to low

Popularity from low to high

Price from high to low

Price from low to high

Used products

New products

Self products

Purchase

Update date< · 2020-09-25

autotrophyAnritsu MP2100B Anritsu MP2100B sampling oscilloscope

Condition Warranty Time Option Location
70% new 12month --
Equipment Introduction:

For 10/40G Multichannel Optical Module/Device R&D and Manufacturing The BERTWave MP2100B is an all-in-one test set with built-in BERT and available sampling oscilloscope supporting evaluation of optical modules, including BER measurements, Eye Mask tests, Eye pattern analyses, etc. A BERT and sampling oscilloscope are required measuring instruments for evaluating optical modules used by optical communications systems. Previous evaluations of optical modules, such as QSFP+ and SFP+ modules, required provision of a separate BERT and sampling oscilloscope. However, the BERTWave MP2100B incorporates a BERT supporting from one up to 4 channels as well as an optional sampling oscilloscope in a single, compact, 18 cm deep cabinet, slashing equipment investment costs and saving bench-top space. In addition, the BERTWave MP2100B reduces measurement times by eliminating the need to change cable connections at simultaneous BER measurements, Eye Mask tests, and Eye pattern analyses. Additionally, adding the SFP+ plug-in port supports optical BER measurements. The BERTWave MP2100B BERT function supports BER measurements at speeds ranging from 125 Mbit/s to 12.5 Gbit/s; its available built-in 4ch BERT option makes it easy to configure test systems for multichannel modules, such as QSFP+ and AOC. Further, in addition to supporting BER measurements for differential signals, it also supports Eye Mask and Eye pattern Measurements. The BERTWave MP2100B sampling oscilloscope has a bandwidth of 25 GHz (typ.) for electrical interfaces and a bandwidth of 9 GHz (typ.) for optical interfaces. In addition, up to six optional Bessel filters can be built-in for measuring optical signals using the scope. Using these filters, MP2100B supports extinction ratio measurements, Eye Mask tests and Eye pattern analyses for various applications. Further, the scope has a Fast Sampling Mode to secure the fastest high-speed measurements; sampling speeds of up to 150 ksample/s are supported by Fast Sampling Mode, which is 1.5 times faster than legacy models and supports time-saving high-speed Eye Mask tests and Eye pattern analyses. Using the Jitter Analysis MX210001A software facilitates easy all-in-one simultaneous Jitter analysis, Eye pattern and Eye Mask measurements and the 150 ksample/s sampling speed makes even more efficient use of measurement time. Combined use with MATLAB® supports waveform dispersion measurements for specific signals, such as WDP, TWDP, and dWDP waveforms. Last, the Transmission Analysis MX210002A software adds functions for analyzing device transmission (S21 gain and phase), plus a De-Embedded waveform simulation function executed by linear equalizer, filter, and Emphasis calculations. Simultaneous waveform sampling and simulation as well as simultaneous Eye pattern and Eye Mask measurements are supported. Combined use with the MX210001A software also enables simultaneous Jitter measurements of simulated waveforms. Features Built-in 4ch BERT and sampling oscilloscope Simultaneous 4ch Bit Error Rate (BER) measurements High-quality waveform PPG (1 ps rms Jitter) High-input sensitivity (10 mVp-p minimum input sensitivity) High-speed Eye Mask test and Eye pattern analysis at 150 ksample/s max. Supports differential signal BER measurement, Eye Mask test and Eye pattern analysis Up to six built-in Bessel filters for full-featured application support Compact (18 cm deep) test set for optical module evaluation Simultaneous measurement of BER, Jitter, Eye pattern and Eye Mask Supports WDP measurements Calculates optimum values for sampling simultaneously with equalizer and emphasis values to display Eye Pattern Simultaneous Eye Pattern, Eye Mask and Jitter measurements of simulated waveform

More>>

consultation>>

0755-86016691

Purchase

Update date< · 2020-09-24

autotrophyEIDEN/营电 MSR3100A Eiden MSR3100A signal generator

Condition Warranty Time Option Location
70% new 12month --
Equipment Introduction:

consultation>>

0755-86016691

Purchase

Update date< · 2020-09-25

autotrophyKeysight 8487A Keysight 8487A power sensor

Condition Warranty Time Option Location
70% new 12month --
Equipment Introduction:

Keysight / Agilent 8487A Power Sensor, 50 MHz to 50.0 GHz, 1 µW to 100 mW, -30 to +20 dBm The 8487A power sensor is designed for use with the 435A/B, 436A, 437A, 438A, 70100A, EPM series, EPM-P series, E1416A, N1911A, N1912A, N1913A, and N1914A power meters. The 8487A provides extraordinary accuracy, stability, and lower SWR. Features: Frequency Range: 50 MHz to 50 GHz Measurement range: 1 µW to 100 mW ( -30 dBm to +20 dBm) 50 ohm impedance 2.4 mm(m) connector Excellent SWR for reducing mismatch uncertainty Shipping Weight: 2 lb

More>>

consultation>>

0755-86016691

Purchase

Update date< · 2020-09-24

autotrophyAgilent 11613A Agilent 11613A Power Metering Range Calibrator

Condition Warranty Time Option Location
70% new 12month --
Equipment Introduction:

Key Features & Specifications Verification of full-scale meter readings on all ranges and meter tracking Polarity switch that tests the auto-zero circuit Calibration Functions: Outputs corresponding to meter readings of 3, 10, 30, 100, and 300 uW; 1, 3, 10, 30, and 100 mW Calibration Uncertainty: ±0.25% in all ranges Power: 100, 120, 220, or 240 Vac +5% -10%, 48 - 440 Hz, less than 10VA Size: 133 mm W x 89 mm H x 216 mm D (5.25 in x 3.5 in x 8.5 in) Description The Keysight 11683A range calibrator is specifically designed for use with the EPM, EPM-P series, E1416A and the discontinued 70100A and 435/6/7/8A power meters.. It allows verification of full-scale meter readings on all ranges, as well as meter tracking. Simply connect the cable between the power meter and calibrator. The CAL ADJ control on the power meter is used to set the meter to full scale on the 1 mW range.

More>>

consultation>>

0755-86016691

Purchase

Update date< · 2020-09-25

autotrophyKeysight 82351B 

Condition Warranty Time Option Location
new days -- 1
Equipment Introduction:

consultation>>

0755-86016691

Purchase

Update date< · 2020-09-24

autotrophyAgilent 83485B optical / electrical module

Condition Warranty Time Option Location
new days --
Equipment Introduction:

Key Features & Specifications 30 GHz optical channel for 9/125 fibers Wavelength range: 1000-1600 nm Reference receiver capability (9.953 Gb/s) 40 GHz electrical channel with 2.4 mm male input Compatibility 83480A Digital Communications Analyzer Mainframe 86100A/B/C Infiniium DCA/DCA-J Mainframes

More>>

consultation>>

0755-86016691

Purchase

Update date< · 2020-09-24

autotrophyEXFO T100S-HP-C EXFO T100S-HP-C High Power Continuous Tunable Laser

Condition Warranty Time Option Location
70% new 12month --
Equipment Introduction:

main advantage: Basic power ≥ +10 dBm Extended range power ≥ +8 dBm Dynamic range over 90 dB Continuously tunable range up to 200 nm Wavelength accuracy <± 20 pm Scan and step operation application: Optical fiber transmission test Passive optical component testing Optical amplifier test Film growth monitoring Optical collimation Fiber Optic Sensor Spectral analysis Interference measurement description: The complete product portfolio of T100S-HP includes 6 continuously tunable lasers covering the 1240 to 1680 nm wavelength range: /O+Model: 1240-1380 nm /O Model: 1260-1360 nm /ES model: 1350-1510 nm /SCL model: 1440-1640 nm /CL model: 1500-1630 nm /CLU model: 1500-1680 nm With the success of the trend-setting TUNICS series products, T100S-HP combines high power and low spontaneous emission. It is ideal for scanning and stepping applications: The /O and /CL lasers have a minimum output power of 10 dBm and are dedicated to major telecom applications. The minimum output power of /O+, /ES, /SCL and /CLU lasers is 8 dBm, and the available wavelength range provided is the largest among existing similar products, so only 3 lasers can cover from 1240 to 1680 nm, 8 dBm The full telecommunications band. These tests can be done by combining /O+, /ES and /CLU lasers.

More>>

consultation>>

0755-86016691

Friendship recommendation

Cooperative client:

kuaidi100IccszC-fol嘉惠捷

more>>

Domestic instrument:

more>>

Import instrument:

keithleyTektronixkeysight

more>>

Metrology calibration:

more>>

Copyright © Copyright © 2007 All Rights Reserved. Copyright© 2003-2015 Shenzhen Haochen Electronic Technology Co.,ltd . All Rights Reserved.   [粤ICP备14101712号-1] [Legal Adviser]

Address:8th Floor, NO.221, Niucheng Road, Xili Town,Nanshan District, Shenzhen, Guangdong Province, China,518055

QQ online service:  Service hotline:0755-86016691  Tel:13715327187  Fax:+86 0755-86641139-816

E-mail:[email protected]